12
Note. After connecting the appliance check all ttings for gas leaks e.g. with soapy
water.
Donotcheckthettingswithopenre!
INSTALLATION
Notes for the technician
The tter should:
• Bear a valid certicate of gas permit
• Have studied the contents of the appliance’s type plate containing the suitable
type of gas. Compare the data with the characteristics of the gas available in the
network.
• Check the following:
- ventilation capacity, incl. air exchange in the kitchen,
- tightness and sealing of the gas ttings,
- effectiveness and correct operation of all the functional elements.
• Adjust the settings of the gas control knobs with the washers included to ensure
the igniters work properly and the entire system is leak-proof;
- check the operation of the igniters and leak seal,
- remove the knob if working incorrectly, and adjust bi introducing washer(s) onto
the valve spindle,
- check the operation of the igniters and leak seal,
- secure the system with a tight washer and put the knob handle on.
• Issue a certicate of connecting the appliance and inform the user of the operating
activities.
The cooktop is equipped with an R1/2” connecting pipe for gas connection. If the appliance
is intended for use with LPG (propane – butane), a Ø 8 x 1 mm hose coupling is threaded
onto the connector.
Make sure the gas connecting pipe does not come in contact with the metal components of
the cooktop.
Allthecouplingsandjointsmustbetightlysealed.
NOTE!
Installationandservicemustbeperformedbyaqualiedandlicensedinstal-
ler, service agency or gas supplier. All the relevant safety regulations must be
observed.