OPERATION
Please make sure you have read and understood the entire operating manual. Do
follow the instructions to ensure safe and effective operation of your cooktop.
NOTE
The appliance uses gas, which is a ammable and explosive substance. Thus, it is
necessary for the cooktop to be connected to a gas network which supplies the gas
type for which the appliance is suitable.
Installation and service must be performed by a qualied installer, service agency
or gas supplier.
Please check the type plate for the information concerning the suitable gas type for
your appliance.
NOTE
The cooktops delivered by the supplier come with the burners which are suitable
for burning the type of gas which is quoted in the type plate and in the guarantee
certicate. The type plate is tted at the bottom panel of the appliance. The following
must be carried out if converting to another gas type is required:
- nozzles must be replaced (see assembling table),
- reduced valve ow rate must be adjusted.
Converting the unit to another gas type
Only a licensed and authorised technician may carry out this job.
If the available gas type is different from that provided in the type plate of the appliance (G 20
(GZ 50) 20 mbar, the burner nozzles should be replaced and ame adjusted.
Table 1
Converting the unit to another gas type
Gas type Nozzlediameter
Small Medium Large WOK
2H (G20/20 mbar)
69 97 110 131
3B/P(G30/30 mbar)
50 68 78 86
2E (G20/20 mbar)
69 97 110 131
2Lw (G27/20 mbar)
75 106 121 136
2Ls (GZ-350/13 mbar)
96 131 147 165
3B/P(G30/37 mbar)
44 64 72 82
3+ (G28-30/37 mbar)
50 68 78 86
2H (G20/25 mbar)
69 97 110 131